Fire Detection & Alarm System

Fire Detection & Alarm System

NFPA regulations provide requirements for the installation, performance, testing, inspection, and maintenance of the fire alarm system. Regulation also covers wiring of a fire alarm system. NFPA 72, National Fire Alarm and Signalling Code covers the requirements for installation performance  of fire alarm systems. System requires visible signalling if the ambient sound pressure level is above 105 dBA.

NFPA 72 addresses several means of transmitting alarm and other signals from a fire alarm system at a protected premise to a supervising station. The most widely used means is a digital alarm communicator system.

These systems use a digital alarm communicator transmitter (DACT) connected through two transmission channels.

The Code requires the primary channel to be a telephone line. The secondary channel can be a second telephone line, or one of 6 other transmission means

Fire Fighting & Protection System

Fire Fighting & Protection System

Fire protection within a structure is a system that relies on all of its components. The building is designed in compliance with the latest QCS and QCDD regulations by the architect and consultants. Firefighting system comprises of sprinklers, fire extinguishers and various panels interfaced with electrical and ventilation system that need to be shut down during a fire situation. Benchmark carries out supply and installation of firefighting and protection system depending on the requirement of the main contractor/client with high quality technical skills and expertise.

Central Air Conditioning & Ventillation System

Central Air Conditioning & Ventillation System

Benchmark specializes in design, supply, install, test and commissioning of central air conditioning systems to suit the commercial and residential building as per local and international codes and practices.

Our list of projects includes

  • Residential,
  • Commercial,
  • Worship places,

and type of installation varies from

  • Central DX system,
    To central chilled water system to suit the client requirements.
  • Our core idea of providing the most economical and long lasting system to client has given us the identity of being professional and expertise identity in the local market.

We also supply and install the fire safety ventilation system related pipeline work for high rises and car park as per local QCDD standards as part of HVAC installation or independent ventilation system for residential building as per local codes and standards.

 

 

 

 

Electrical Installation

Electrical Installation

Benchmark executes electrical work in a residential, commercial and industrial setting, with widely varying hours and working conditions, depending on the main contractor/client/employer and their specific job description. We focus on either constructions and/or maintenance. Once engaged to contract works.

Our responsibilities include:

  • Different tasks, in areas that include customer service and administrative work, installation and maintenance. Benchmark executes electrical work in a residential, commercial and industrial setting, with widely varying hours and working conditions, depending on the main contractor/client/employer and their specific job description. We focus on either constructions and/or maintenance.

Once engaged to contract works,  our responsibilities include:

  • Different tasks, in areas that include customer service and administrative work, installation and maintenance.

Customer service and administrative work often includes:

  • contacting customers,
  • scheduling appointments and completing regulatory requirements, such as KAHRAMAA permit applications
  • and periodic coordination with KAHRAMAA during the course of execution of new project that facilitate to KAHRAMAA planning, installation & consumer sections inspections and transmission cable laying and Kw/hr meter fixing and finally energizing of new premises.
  • Our successfully completed works warranty 365 – 400 days against faulty materials and bad workmanship

Construction duties include:

  • surface and/or concealed bending conduit,
  • laying conduits and its accessories,
  • stringing wires,
  • fixing distribution boards;
  • dressing the cables
  • and fixing miniature circuit breakers within,
  • fixing of Sub-Mains and Main switchboard,
  • fixing cable trunk and trays,
  • fixing over ground and laying underground cables,
  • fixing final accessories such as switches & sockets,
  • lighting fixtures and chandeliers and machineries.
  • Testing, measuring and finally energizing premises with KAHRAMAA engineering team.

Maintenance duties include:

  • inspecting electrical equipment,
  • replacing worn parts and repairing complex devices.
  • Electrical Code: KAHRAMAA has a code of practice which is strictly based on knowledge of codes and regulations and passing an examination.
  • KAHRAMAA requires contractor’s engineers and supervisors successfully completed test conducted by URBAN PLANNING & DEVELOPMENT AUTHORITY (UPDA). To become a qualified electrical contractors generally
CCTV AND PA SYSTEM

CCTV AND PA SYSTEM

Various ranges of highly stable and quality products to satisfy the market are available at Benchmark Trading with advanced technology based on customer’s requirements and prompt response.

Access Control System

PROGENY/UK

Video Surveillance System

VICON/UK

Building Management System

TREND/UK

Public Address System

TOA /TAIWAN